Protection Coordination,
Arc Flash
and Disturbance Analysis

APS provides specialist protection coordination, relay setting verification and disturbance analysis services for transmission, distribution, renewable generation, industrial, data centre and private power networks.

Protection Coordination, Arc Flash and Disturbance Analysis
Protection Coordination, Arc Flash and Disturbance Analysis
PowerFactory, ETAP, EMTP®  PSCAD™/EMTDC™
Protection Coordination
Arc Flash
and
Disturbance Analysis
Service Scope

Protection Coordination,
Arc Flash
and Disturbance Analysis

Specialist studies for protection coordination, relay setting verification, fault clearance performance, disturbance analysis and protection system review for HV, MV and LV electrical networks.

Overview


APS provides specialist engineering studies for protection coordination, relay setting verification and disturbance analysis across transmission, distribution, renewable generation, BESS, industrial, data centre and private network installations.Protection systems are required to operate correctly under a wide range of credible network conditions, including changing fault levels, weak-grid operation, inverter-based generation, transformer energisation, large motor starting, parallel feeders, cable-dominated networks, embedded generation and complex industrial load behaviour.In these networks, protection settings should not be treated as a simple relay configuration exercise. A structured engineering assessment is required to confirm that each protection device operates with suitable sensitivity, selectivity, speed, security, dependability and stability under the expected fault and operating conditions.APS supports protection studies from early design and protection philosophy review through to detailed relay setting preparation, independent setting review, commissioning support, protection audit and post-event investigation. The study may include short-circuit assessment, relay grading, time-current coordination, overcurrent and earth-fault protection, directional protection, distance protection, transformer protection, generator protection, motor protection, feeder protection, busbar protection, breaker failure protection and interface protection for grid-connected installations.

Studies can be carried out using industry-recognised tools such as DIgSILENT PowerFactory, ETAP, EMTP®, PSCAD™/EMTDC™ and manufacturer relay configuration software. This allows protection performance to be assessed not only using conventional short-circuit studies, but also under dynamic and transient conditions where CT saturation, CVT response, DC offset, transformer inrush, harmonics, converter control response, fault resistance, weak infeed conditions, power swings and protection logic may influence relay operation.APS also provides disturbance and event analysis services based on relay disturbance records, COMTRADE files, event logs, fault records, breaker operation records and relay setting files. This service is particularly useful after unexpected tripping, delayed clearance, nuisance operation, breaker failure, unexplained outages or suspected protection maloperation.By combining recorded waveforms, relay event reports, protection settings, network modelling and engineering judgement, APS can help identify the likely sequence of events, assess whether the protection system operated correctly and recommend practical corrective actions.

Key Services


APS provides study-led protection coordination and disturbance analysis services for projects where reliable, selective and secure fault clearance is required. The service combines short-circuit assessment, relay setting calculations, coordination review, setting file verification, disturbance record analysis and practical protection engineering judgement.

  • Protection coordination studies for HV, MV and LV networks More info
  • Short-circuit studies to support relay setting calculations More info
  • Relay grading and time-current coordination studies More info
  • Overcurrent, earth-fault and directional protection coordination More info
  • Distance protection zone setting and verification More info
  • Transformer differential and restricted earth-fault protection review More info
  • Busbar, backup and breaker failure protection assessment More info
  • Interface protection and grid-connection protection review More info
  • Protection coordination for industrial facilities and private networks More info
  • Review of relay setting files and manufacturer configuration outputs More info
  • Verification of CT and VT ratios, polarity, burden and suitability More info
  • Assessment of CT saturation and transient response on protection performance More info
  • Review of protection logic, interlocking, blocking and trip schemes More info
  • Verification of CT and VT ratios, polarity, burden and suitability More info
  • Arc-flash clearing-time support based on protection operating times More info
  • Preparation of protection setting reports and calculation notes More info
  • Protection audit and selectivity review of existing installations More info
  • Independent review of OEM, EPC or contractor protection setting proposals More info

Disturbance and Event Analysis


Disturbance and event analysis is required when the actual behaviour of the power system or protection scheme needs to be understood after a fault, trip, outage or abnormal operating condition.APS reviews relay disturbance records, COMTRADE files, event logs, setting files, breaker operation records and recorded voltage/current waveforms to identify the likely sequence of events and determine whether the protection system operated as expected.Where required, events can be reconstructed using DIgSILENT PowerFactory, EMTP® or PSCAD™/EMTDC™ to support root-cause analysis, relay performance verification and corrective action planning

  • Analysis of COMTRADE files recorded by protection relays More info
  • Fault and event investigation using SIGRA and similar tools More info
  • Review of relay event reports and disturbance records More info
  • Analysis of voltage and current waveforms during faults and trips More info
  • Identification of fault type, fault location and likely fault inception sequence More info
  • Assessment of relay pickup, trip timing and protection element operation More info
  • Review of breaker opening time and fault-clearing sequence More info
  • Investigation of unwanted tripping, delayed tripping and failure to trip More info
  • Assessment of protection maloperation, miscoordination and nuisance operation More info
  • Comparison of recorded events against relay settings and expected behaviour More info
  • Reconstruction of events using PowerFactory, EMTP® or PSCAD™/EMTDC™ where required More info
  • EMT-based analysis of complex protection events in converter-rich networks More info
  • Investigation of CT saturation, DC offset, inrush, harmonics and transient effects More info
  • Root-cause analysis and recommendation of corrective actions More info
  • Preparation of technical event investigation reports for asset owners, EPCs, developers, utilities and insurers More info

Typical Applications


These studies are suitable for projects where protection performance, relay coordination, fault clearance time, backup operation, grid-code compliance or post-event behaviour must be technically justified.

  • High-voltage substations
  • Transmission and distribution networks
  • Solar farms and wind farms
  • Battery energy storage systems
  • Generator connections
  • Data centres and mission-critical facilities
  • Industrial plants and manufacturing sites
  • Oil and gas facilities
  • Mining and heavy-load facilities
  • Water treatment and pumping stations
  • Large private MV networks
  • Grid-connected generation projects
  • Sites affected by nuisance tripping or unexplained outages
  • Projects requiring independent protection setting review
  • Existing installations requiring protection audit or selectivity review

Technical Value


The objective of the study is to provide a technically justified assessment of protection performance before incorrect settings, weak coordination or protection maloperation become safety, compliance or operational issues.APS combines short-circuit studies, relay setting calculations, protection coordination review, manufacturer relay documentation, disturbance record analysis and advanced simulation to help clients understand how the protection system will operate under credible fault and network conditions.The assessment supports early design decisions, relay setting preparation, protection philosophy development, commissioning verification, grid-code compliance, fault investigation, protection audit and corrective action planning.By combining RMS and EMT-based simulation, relay setting review, COMTRADE analysis, event reconstruction and practical protection engineering judgement, APS helps clients improve system reliability, reduce outage risk, avoid unnecessary disconnection, support safe fault clearance and demonstrate that protection coordination requirements have been properly considered.